建立有效的校准程序:哪些仪器需要校准?哪些仪器不需要校准?

来源:Pharmaceutical Online
Calibration Determination
校准决定

An effective calibration program must firstidentify which items must be calibrated. The following items must becalibrated: items used to make a release (quality) decision, items used to setcritical process settings, items used to monitor critical process(environmental) conditions, and items used to make measurements supportingequipment product, process, design verification/validation/qualificationactivities.
一个有效的校准程序必须首先确定哪些测量项目必须校准。以下测量项目必须进行校准:用于做出放行(质量)决定的测量项目,用于设置关键工艺参数的项目,用于监测关键工艺(环境)条件的项目,以及用于测量支持设备、工艺、设计验证/验证/确认活动的仪器。
 
Items used to make a release (quality)decision or used to approve materials, components, subassemblies, assemblies,and finished goods at incoming, in-process, or final inspection must becalibrated to ensure compliance with predetermined specifications. 
用于做出放行(质量)决定或用于在入库、中控或最终检验中进行物料、组分、组件、和成品批准的测量项目必须进行校准,以确保符合预定的标准。
 
Items used to set critical process settingsmust be calibrated. Items that set critical process settings, such astemperature, pressure, time, etc., are examples of items typically used tocontrol a process to ensure process outputs meet predetermined specifications.
用于设置关键工艺参数的项目必须进行校准。设置关键工艺参数的项目,如温度、压力、时间等,是典型的用于控制工艺的项目,以确保工艺输出满足预定的标准。
 
Items used to monitor critical process(environmental) conditions must be calibrated. Items used to monitor criticalprocess conditions such as pressure differential, temperature, and humidity areexamples of items typically used to monitor critical process conditions toensure process outputs meet predetermined specifications.
用于监测关键工艺(环境)条件的项目必须进行校准。用于监测关键工艺条件(如压差、温度和湿度)的项目是常见的关键工艺条件监测项目以确保工艺输出符合预定标准。
 
Items used to make measurements supportequipment product, process, design verification/validation/qualificationactivities include those that are used to approve materials, components,subassemblies, assemblies, and finished goods, set critical process settings,and monitor critical process (environmental) conditions.
用于测量支持设备、工艺、设计确认/验证/确认活动的项目,包括用于物料、组分、组件、和成品批准、设置关键工艺参数和监测关键工艺(环境)条件的项目。
 
Reference Only Calibration Not Required
用于参考目的不需要校准
 
Instruments that are not used to get exactmeasurements but are used only to obtain status information do not requirecalibration. Table 2 provides some examples of when calibration may and may notbe required.
不用于获得精确测量而仅用于获取状态信息的仪器不需要校准。表2提供了一些可能需要和可能不需要校准的示例。

Table2: Calibration not required/calibration required examples.
表2:不需要校准/需要校准示例。
 
Another simple test that I like to use todetermine if calibration is required is to apply this simple test: If the itemwas covered (not visible), can the process be set up, monitored, and operated correctly?If the answer is no to any of these questions, the item must be calibrated;otherwise, calibration is not required.
另一个我喜欢用来确定是否需要校准的简单测试:如果没有该项目,过程是否可以被正确设置、监测和操作?如果这些问题的答案都是否定的,就必须对仪器进行校准;否则,不需要校准。


       文章来源:GMP办公室

       本网站刊载的所有内容,包括文字、图片、音频、视频、软件等,如非标注为“原创”,则相关版权归原作者所有,如原作者不愿意在本网站刊登相关内容,请及时通知本站,我们将第一时间予以删除。


上一篇:新冠病毒疫苗该怎么打?中国权威机构发布接种指南